Next meeting 14th UFM Meeting · 23 Mar 2027 · Bristol Save the date →

Hygrothermal and air change measurements in ventilated attics, Nordic climate

Field 28 MB

Temperature and relative humidity at 10-minute intervals inside six ventilated attics of Tampere University test buildings (2021-2022), plus CO2 tracer-gas air change rate measurements. Useful for attic ventilation and infiltration modelling.

Get the data

Licence
CC BY 4.0 Free to use and share, including commercially, as long as you credit the creators.
Size
28 MB · 6 attics, 2021-2022

How to cite

Valovirta, I., Hietikko, J., Tuominen, E., Yletyinen, K., & Vinha, J. (2024). Hygrothermal performance of ventilated attics in Nordic climate, field study 2021-2022 [Data set]. Zenodo. https://doi.org/10.5281/zenodo.11083067

Check the repository for the citation its authors prefer.

Details

Resource
Measurements
Method
Field, Tracer gas, Indoor sensors
Space
Attic or building envelope
Topic
Ventilation
Quantities
Temperature, Humidity, Concentration, Ventilation rate
Location
Tampere, Finland · more from Finland
Year
2024
Creators
Valovirta, Ilkka; Hietikko, Jaakko; Tuominen, Eero; Yletyinen, Kaapo; Vinha, Juha
Institution
Tampere University