Experiments on a mechanically ventilated double-skin facade in a climate simulator
Field2 MB
Steady-state measurements on a full-scale single-storey double-skin facade with venetian blinds, run in outdoor-air-curtain and supply-air modes at several ventilation rates under winter and summer boundary conditions with a solar simulator. Contains cavity temperatures, airflow and heat-flux data for validating facade airflow and thermal models.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
2 MB
How to cite
Aleksandar, J., & Francesco, G. (2022). An experimental data set for analysis of the thermophysical behavior of a single-story mechanically ventilated double-skin façade (DSF) in fixed boundary conditions corresponding to winter/mid-season and summer cases [Data set]. Zenodo. https://doi.org/10.5281/zenodo.6482697
Please also cite the publication below that describes it.
One-minute BMS time series covering zone temperature, CO2, setpoints and actuator signals, plus hourly electricity data, from schools, medical centres, care facilities and a sports arena, 2022-2025. Useful for ventilation and indoor air quality analysis and for data-driven HVAC control.
3D models and measurements of air speed, air temperature and server power at 1-10 s intervals in a small server room, under idle to 100% load scenarios. Useful for validating CFD of data-centre cooling airflow.
Experimental temperature data, STL geometries and OpenFOAM case setups and results for an air-cooled data centre, before and after retrofit. Useful for validating CFD of cooling airflow in technical rooms.
Laboratory office-room measurements of CO2 in the room and in supply/exhaust ducts, plus temperature, humidity, pressure, variable VAV airflow and ground-truth occupant counts. Useful for ventilation-rate estimation and demand-controlled ventilation.
Air velocity measurements above an operating table in a laboratory operating room with mixing and unidirectional ventilation, varying patient/staff presence and supply temperature. Useful for validating operating-room airflow CFD.
Case-by-case processed results for indoor temperature, CO2, particulate matter and energy use under different ventilation scenarios in a school kitchen, for comparing ventilation strategies.
From Zenodo, added 2026-11-15.
Listed there as “An experimental data set for analysis of the thermophysical behavior of a single-story mechanically ventilated double-skin façade (DSF) in fixed boundary conditions corresponding to winter/mid-season and summer cases”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.