Indoor air quality and mechanical ventilation in low-income California apartments
Field25 MB
One-week time-resolved PM2.5, NO2, formaldehyde and CO2 plus measured range hood and exhaust fan airflows in 23 apartments with gas cooking. Useful for studying ventilation performance and indoor pollutant dynamics in homes.
CC0No restrictions: dedicated to the public domain. Credit is appreciated but not required.
Size
25 MB · 23 apartments at 4 properties
How to cite
Zhao, H., Chan, W., Cohn, S., Delp, W. W., Walker, I. S., & Singer, B. C. (2020). Indoor air quality in new and renovated low‐income apartments with mechanical ventilation and natural gas cooking in California [Data set]. Zenodo. https://doi.org/10.7941/D1T050
Check the repository for the citation its authors prefer.
One-week monitoring in 70 new California homes. Includes time-resolved indoor CO2 and formaldehyde, indoor/outdoor PM2.5 and exhaust fan operation, plus measured mechanical airflows and envelope and duct leakage. Useful for ventilation and infiltration analyses.
Results from coupled CONTAM/EnergyPlus co-simulations of zoned smart ventilation strategies in new California dwellings. Covers ventilation energy and occupant exposure to CO2, moisture, particles and a generic contaminant.
One-minute BMS time series covering zone temperature, CO2, setpoints and actuator signals, plus hourly electricity data, from schools, medical centres, care facilities and a sports arena, 2022-2025. Useful for ventilation and indoor air quality analysis and for data-driven HVAC control.
Air velocities measured on an HTM 03-01 grid at 1 m and 2 m below the canopy (three repeats), processed means and uncertainties, and the CAD geometry. Useful for validating CFD of ultra-clean ventilation airflow and particle entrainment.
Laboratory office-room measurements of CO2 in the room and in supply/exhaust ducts, plus temperature, humidity, pressure, variable VAV airflow and ground-truth occupant counts. Useful for ventilation-rate estimation and demand-controlled ventilation.
Case-by-case processed results for indoor temperature, CO2, particulate matter and energy use under different ventilation scenarios in a school kitchen, for comparing ventilation strategies.
From Zenodo, added 2026-11-15.
Listed there as “Indoor air quality in new and renovated low‐income apartments with mechanical ventilation and natural gas cooking in California”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.