Cough-generated bioaerosol dispersion and ventilation removal in a room-scale chamber
Field5 MB
Size-resolved particle concentration time series (6 s, 1 s for cough) at 1-4 m from a cough source and culturable E. coli data at several relative humidities in a ventilated room-scale chamber. Useful for validating indoor aerosol dispersion, deposition and ventilation removal models.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
5 MB · 12 files; 3 RH levels, 4 distances
How to cite
Dong, H., Medina, T., Kohn, T., & Licina, D. (2026). Rapid Early Inactivation and Ventilation-Driven Removal of Cough-Generated E. coli Aerosols in a Room-Scale Chamber [Data set]. Zenodo. https://doi.org/10.5281/zenodo.22228510
Check the repository for the citation its authors prefer.
Raw full-scale measurements of air velocity, temperature and particle concentration at breathing height in a mixing-ventilated test room, under varied exhalation flow velocities and directions. Useful for validating indoor CFD of airborne particle transport.
About 150,000 records of CO2, temperature, humidity and pressure from IoT devices spread across an office workplace. Useful for studying ventilation adequacy and infection risk.
Particle concentration measurements in a 40.8 m3 hospital room with two breathing thermal manikins (patient and health worker), comparing air cleaner positions, mechanical ventilation and combinations at 3.67 ACH. Useful for validating indoor dispersion and airborne transmission models.
About 73,000 observations of CO2, temperature and humidity from low-cost SCD30 nodes in six classrooms at two schools (Vilafamés and Vall d'Alba), May 2020 to June 2021. Useful for assessing classroom ventilation under COVID-19 measures.
Full input and output files of FDS simulations of respiratory aerosol dispersion in four indoor environments. They cover three breathing manoeuvres, two emission levels and two ventilation scenarios. Useful for airborne transmission and ventilation studies.
Processed tracer concentrations, dilution ratios, contaminant removal efficiency and infection probability from a test chamber set up as a hospital room. It covers several air distribution strategies and clinical activities, with metadata on cases and measurement points. Useful for validating indoor ventilation and dispersion models.
From Zenodo, added 2026-11-15.
Listed there as “Rapid Early Inactivation and Ventilation-Driven Removal of Cough-Generated E. coli Aerosols in a Room-Scale Chamber”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.