Data portal · Topic
Airborne transmission datasets: exhaled jets, aerosols and ventilation
Measurements and simulations of how exhaled air and aerosols spread through a room: cough, speech and breathing jets, aerosol dispersion under different ventilation set-ups, and studies linking airflow to far-field infection risk.
- 21 resources
- 9 field
- 1 lab
- 5 simulation
- 6 tools & geometry
All 21 resources, largest first
Nothing on this page for that setting. Show all 21.
-
SUEWS input state, forcing and UV data with output for 12 London neighbourhoods, plus grid-wide risk metrics for Greater London. Useful for studying how urban form and meteorology affect outdoor ventilation and airborne infection risk.
Outdoor Simulation Simulation outputCase setup Mesoscale model
-
Data from CFD simulations of indoor airflow and passive tracer spread on the 8th floor of Pyeongtaek St. Mary's Hospital, in six cases with different outdoor wind directions and mechanical ventilation settings. Useful for studying airborne spread between hospital rooms.
Indoor–outdoor Simulation Simulation output RANS
-
CUDA Python finite-difference solver of compressible Navier-Stokes with heat and CO2 transport and periodic nasal breathing of a seated person in a non-ventilated 5.75 x 2.55 x 2.85 m room. Useful for studying thermal plumes, exhalation jets and indoor aerosol/CO2 spreading.
Indoor Simulation Software & toolsCase setup DNS
-
Full input and output files of FDS simulations of respiratory aerosol dispersion in four indoor environments. They cover three breathing manoeuvres, two emission levels and two ventilation scenarios. Useful for airborne transmission and ventilation studies.
Indoor Simulation Simulation outputCase setup LES
-
Raw sensor-grid concentration data and metadata from indoor dispersion experiments used to quantitatively validate LES of indoor dispersion. Useful as validation data for indoor dispersion models.
Indoor Field Measurements Indoor sensors
-
Size-resolved particle concentration time series (6 s, 1 s for cough) at 1-4 m from a cough source and culturable E. coli data at several relative humidities in a ventilated room-scale chamber. Useful for validating indoor aerosol dispersion, deposition and ventilation removal models.
Indoor Field Measurements Indoor sensors
-
Processed tracer concentrations, dilution ratios, contaminant removal efficiency and infection probability from a test chamber set up as a hospital room. It covers several air distribution strategies and clinical activities, with metadata on cases and measurement points. Useful for validating indoor ventilation and dispersion models.
Indoor Field Measurements Tracer gas
-
Processed SF6 tracer concentrations, dilution ratios, contaminant removal effectiveness and infection probability in a double-bed patient room. Tested conditions vary air distribution method, airflow rate, heat gains, visitor posture and location, and privacy curtains. Useful for validating models of indoor dispersion and ventilation.
Indoor Field Measurements Tracer gas
-
Raw full-scale measurements of air velocity, temperature and particle concentration at breathing height in a mixing-ventilated test room, under varied exhalation flow velocities and directions. Useful for validating indoor CFD of airborne particle transport.
Indoor Field Measurements Indoor sensors
-
Data files for several air purifier positions in two elevator cabin models, giving mean age of air on a plane at 1.6 m and infiltration results. Useful for ventilation effectiveness studies and for validating indoor airflow models in small enclosures.
Indoor Simulation Simulation output RANS
-
Code that simulates exposure values for individuals in an environment after coughing or speaking emissions from an infected person, and derives transmission bottleneck sizes. Useful for simple indoor dispersion-based exposure estimates.
Indoor Tools & geometry Software & tools Analytical
-
About 150,000 records of CO2, temperature, humidity and pressure from IoT devices spread across an office workplace. Useful for studying ventilation adequacy and infection risk.
Indoor Field Measurements Indoor sensors
-
CFD of purging flow and airborne infection risk across street-canyon aspect ratios, wind speeds and wall heating.
Outdoor Tools & geometry Simulation output
-
CFD of transient virus-laden particle recirculation and filtration in a room, with airflow patterns and dispersion.
Indoor Tools & geometry Simulation output
-
Water-tank experiment on the coupling of an exhaled jet with motion-induced flow in stratified surroundings.
Indoor Lab Measurements Water flume
-
2D CFD of exhaled droplet dispersion and air change in a street canyon coupled to naturally ventilated buildings.
Indoor–outdoor Tools & geometry Simulation output
-
Inverse CFD with an adjoint method to locate pollutant sources under single-sided ventilation between units.
Indoor–outdoor Tools & geometry Simulation output
-
Particle concentration measurements in a 40.8 m3 hospital room with two breathing thermal manikins (patient and health worker), comparing air cleaner positions, mechanical ventilation and combinations at 3.67 ACH. Useful for validating indoor dispersion and airborne transmission models.
Indoor Field Measurements Indoor sensors
-
About 73,000 observations of CO2, temperature and humidity from low-cost SCD30 nodes in six classrooms at two schools (Vilafamés and Vall d'Alba), May 2020 to June 2021. Useful for assessing classroom ventilation under COVID-19 measures.
Indoor Field Measurements Indoor sensors
-
CFD of single-sided buoyancy-driven ventilation and pollutant cross-transmission in a multistorey building with different window types.
Indoor–outdoor Tools & geometry Simulation output
-
Field tracer-gas measurements of air infiltration and inter-flat spread with air change rates and cross-infection risk assessment.
Indoor Field Measurements Tracer gas