Exhaled particle distribution, velocity and temperature in a ventilated test facility
Field1 MB
Raw full-scale measurements of air velocity, temperature and particle concentration at breathing height in a mixing-ventilated test room, under varied exhalation flow velocities and directions. Useful for validating indoor CFD of airborne particle transport.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
1 MB
How to cite
Qin, P., de Lange, A., van Hooff, T., Traversari, R., & Loomans, M. (2025). Experimental and CFD analysis of particle distribution in a controlled test facility: Impact of exhalation flow velocity and direction (Experimental Dataset v1.1.0) [Data set]. Zenodo. https://doi.org/10.5281/zenodo.21474288
Check the repository for the citation its authors prefer.
Eindhoven University of Technology, Netherlands · more from Netherlands
Year
2025
Creators
Qin, Peng; de Lange, Anneloes; van Hooff, Twan; Traversari, Roberto; Loomans, Marcel
Institution
Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands; Department of Buildings and Energy Systems, TNO Netherlands Organization for Applied Scientific Research, Delft, the Netherlands
Size-resolved particle concentration time series (6 s, 1 s for cough) at 1-4 m from a cough source and culturable E. coli data at several relative humidities in a ventilated room-scale chamber. Useful for validating indoor aerosol dispersion, deposition and ventilation removal models.
About 150,000 records of CO2, temperature, humidity and pressure from IoT devices spread across an office workplace. Useful for studying ventilation adequacy and infection risk.
Particle concentration measurements in a 40.8 m3 hospital room with two breathing thermal manikins (patient and health worker), comparing air cleaner positions, mechanical ventilation and combinations at 3.67 ACH. Useful for validating indoor dispersion and airborne transmission models.
About 73,000 observations of CO2, temperature and humidity from low-cost SCD30 nodes in six classrooms at two schools (Vilafamés and Vall d'Alba), May 2020 to June 2021. Useful for assessing classroom ventilation under COVID-19 measures.
Full input and output files of FDS simulations of respiratory aerosol dispersion in four indoor environments. They cover three breathing manoeuvres, two emission levels and two ventilation scenarios. Useful for airborne transmission and ventilation studies.
A year of 10-minute data from 11 social-rental dwellings: CO2, TVOC, temperature, humidity and pressure, plus PIR and door activity, radiator valves, electricity, gas and weather. Useful for residential CO2 and ventilation behaviour studies.
From Zenodo, added 2026-11-15.
Listed there as “Experimental and CFD analysis of particle distribution in a controlled test facility: Impact of exhalation flow velocity and direction (Experimental Dataset v1.1.0)”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.