Multizone simulations of a façade-integrated air handling unit across European climates
Simulation192 cases
Simulation outputs and MATLAB scripts for 192 cases of a dwelling with a façade-integrated AHU with thermoelectric heat exchange. Covers ventilation, IAQ, overheating and energy across four climates.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
4.7 GB · 192 cases
How to cite
Zavřel, V. (2026). Simulation Dataset for Performance Testing of a Façade-Integrated Air Handling Unit with a Thermoelectric Heat Exchanger across European Climates [Data set]. Zenodo. https://doi.org/10.5281/zenodo.20629490
Check the repository for the citation its authors prefer.
Results from coupled CONTAM/EnergyPlus co-simulations of zoned smart ventilation strategies in new California dwellings. Covers ventilation energy and occupant exposure to CO2, moisture, particles and a generic contaminant.
One-minute BMS time series covering zone temperature, CO2, setpoints and actuator signals, plus hourly electricity data, from schools, medical centres, care facilities and a sports arena, 2022-2025. Useful for ventilation and indoor air quality analysis and for data-driven HVAC control.
Processed URANS outputs (regional temperature rise, passive tracer, mean-field sections), surrogate models, reference geometry, input dictionaries and analysis code comparing fan allocations at equal power in a normalised industrial hall. Useful for industrial ventilation design and surrogate modelling.
Air velocities measured on an HTM 03-01 grid at 1 m and 2 m below the canopy (three repeats), processed means and uncertainties, and the CAD geometry. Useful for validating CFD of ultra-clean ventilation airflow and particle entrainment.
Laboratory office-room measurements of CO2 in the room and in supply/exhaust ducts, plus temperature, humidity, pressure, variable VAV airflow and ground-truth occupant counts. Useful for ventilation-rate estimation and demand-controlled ventilation.
Case-by-case processed results for indoor temperature, CO2, particulate matter and energy use under different ventilation scenarios in a school kitchen, for comparing ventilation strategies.
From Zenodo, added 2026-11-15.
Listed there as “Simulation Dataset for Performance Testing of a Façade-Integrated Air Handling Unit with a Thermoelectric Heat Exchanger across European Climates”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.