Mean age of air and infiltration in elevator cabins with air purifiers
Simulation25 MB
Data files for several air purifier positions in two elevator cabin models, giving mean age of air on a plane at 1.6 m and infiltration results. Useful for ventilation effectiveness studies and for validating indoor airflow models in small enclosures.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
25 MB · 17 files, 2 cabin types
How to cite
Fernandez Oro, J. M., & Santamaría Bertolín, L. (2023). Data from "Optimal position of air purifiers in elevator cabins for the improvement of their ventilation effectiveness [Data set]. Zenodo. https://doi.org/10.17811/ruo_datasets.80003
Please also cite the publication below that describes it.
Full input and output files of FDS simulations of respiratory aerosol dispersion in four indoor environments. They cover three breathing manoeuvres, two emission levels and two ventilation scenarios. Useful for airborne transmission and ventilation studies.
Size-resolved particle concentration time series (6 s, 1 s for cough) at 1-4 m from a cough source and culturable E. coli data at several relative humidities in a ventilated room-scale chamber. Useful for validating indoor aerosol dispersion, deposition and ventilation removal models.
Processed tracer concentrations, dilution ratios, contaminant removal efficiency and infection probability from a test chamber set up as a hospital room. It covers several air distribution strategies and clinical activities, with metadata on cases and measurement points. Useful for validating indoor ventilation and dispersion models.
Processed SF6 tracer concentrations, dilution ratios, contaminant removal effectiveness and infection probability in a double-bed patient room. Tested conditions vary air distribution method, airflow rate, heat gains, visitor posture and location, and privacy curtains. Useful for validating models of indoor dispersion and ventilation.
Raw full-scale measurements of air velocity, temperature and particle concentration at breathing height in a mixing-ventilated test room, under varied exhalation flow velocities and directions. Useful for validating indoor CFD of airborne particle transport.
About 150,000 records of CO2, temperature, humidity and pressure from IoT devices spread across an office workplace. Useful for studying ventilation adequacy and infection risk.
From Zenodo, added 2026-11-15.
Listed there as “Data from "Optimal position of air purifiers in elevator cabins for the improvement of their ventilation effectiveness"”. Tags proposed by AI and not yet checked by hand. Spotted a mistake? Tell the portal contacts.