Spatial distribution of CO2 and thermal conditions in a day-care classroom
Field2 MB
Temperature, humidity and CO2 measured at eight points on child and adult breathing planes in a day-care classroom. Eight tests cover combinations of ventilation, conditioning and air cleaning, for assessing indoor air quality and ventilation performance.
CC BY 4.0Free to use and share, including commercially, as long as you credit the creators.
Size
2 MB · 8 experimental tests
How to cite
Moral Luque, J. M., Sánchez Jiménez, J. L., & Ruiz de Adana, M. (2024). Spatial and Temporal Distribution of CO2 and Thermal Comfort Conditions in a Day Care Center [Data set]. Zenodo. https://doi.org/10.5281/zenodo.14497773
Check the repository for the citation its authors prefer.
Particle concentration measurements in a 40.8 m3 hospital room with two breathing thermal manikins (patient and health worker), comparing air cleaner positions, mechanical ventilation and combinations at 3.67 ACH. Useful for validating indoor dispersion and airborne transmission models.
One-minute BMS time series covering zone temperature, CO2, setpoints and actuator signals, plus hourly electricity data, from schools, medical centres, care facilities and a sports arena, 2022-2025. Useful for ventilation and indoor air quality analysis and for data-driven HVAC control.
Laboratory office-room measurements of CO2 in the room and in supply/exhaust ducts, plus temperature, humidity, pressure, variable VAV airflow and ground-truth occupant counts. Useful for ventilation-rate estimation and demand-controlled ventilation.
Case-by-case processed results for indoor temperature, CO2, particulate matter and energy use under different ventilation scenarios in a school kitchen, for comparing ventilation strategies.
One-week time-resolved PM2.5, NO2, formaldehyde and CO2 plus measured range hood and exhaust fan airflows in 23 apartments with gas cooking. Useful for studying ventilation performance and indoor pollutant dynamics in homes.
Simulation outputs and MATLAB scripts for 192 cases of a dwelling with a façade-integrated AHU with thermoelectric heat exchange. Covers ventilation, IAQ, overheating and energy across four climates.
IndoorSimulationSimulation outputSoftware & toolsMultizone model